
diff --git a/config-default.yaml b/config-default.yaml index 203b7dc..44ab97c 100644 --- a/config-default.yaml +++ b/config-default.yaml @@ -1,561 +1,591 @@ ###################################################################### # PvMonit - By David Mercereau : http://david.mercereau.info/contact/ # Licence BEERWARE ###################################################################### ############################## # # NE MODIFIER PAS CE FICHIER ! # copier config-default.yaml dans config.yaml et modifier config.yaml (supprimer tout ce qui ne vous intéresse pas de modifier) # ############################## # Niveau d'affichage des messages printMessage: 0 # 0=0 5=debug printMessageLogfile: false # path or fase # URL data urlDataXml: http://pvmonit.local/data-xml.php # N'utilisez pas 127.0.0.1 mais plutôt l'ip local si vous restez en local (192.168.1.2 ? commande "ip a s" pour l'obtenir, vous ne pouvez pas être en DHCP, mais en IP fixe donc), ou un nom de domain résolu en local et à l'exterieur si c'est publié sur internet tmpFileDataXml: /tmp/PvMonit_data-xml.php.tmp scriptDataXml: /opt/PvMonit/www/data-xml.php dir: bin: /opt/PvMonit/bin/ bin_enabled: /opt/PvMonit/bin-enabled/ lcd: /opt/PvMonit/lcd/ domo: /opt/PvMonit/domo/ bin: php-cli: /usr/bin/php data: ppv_total: false # production total des régulateurs (utilisé si vous avez plusieurs régulateur) conso_calc: false # Calculé avec : la puissance instantané (P du BMV) - ppv_total ppv_total at true for use this #~ dataCheck: # Donnée minimum pour que l'XML soit considéré comme valide #~ PPV: # Production des MPPT #~ regex: (^[0-9]+\.?[0-9]+?$)|(^[0-9]$) #~ number: 2 # Si vous avez 2 MPPT il faut le préciser #~ SOC: #~ regex: (^[0-9]+\.?[0-9]+?$)|(^[0-9]$) # BMV : % SOC #~ P: #~ regex: (^-?[0-9]+\.?[0-9]+?$)|(^-?[0-9]$) # BMV : P #~ PPVT: # Total des PPVT (si plusieurs MPPT #~ regex: (^[0-9]+\.?[0-9]+?$)|(^[0-9]$) #~ CS: # MPPT etat (float, bulk...) #~ regex: ^Off$|Fault$|Bulk|Faible|Abs|Float|On$ #~ Relay: # SmartSolar MPPT Relay ou BMV #~ Si aucun regex n'est précisé alors la vérification ne ce fait pas sur la valeur mais uniquement sur la présence de la donnée cache: dir: /tmp/PvMonit_cache # in tmpfs expir: 15 # in second expirLimit: 60 # If dataCheck error... # Methode de récupération des données VE DIRECT (par USB - vedirect OU serial par Arduino) vedirect: by: usb # usb OR arduino usb: # Binaire de vedirect.py USB bin: /usr/bin/sudo /usr/bin/python /opt/PvMonit/bin/vedirect.py arduino: # Fichier de data YAML enregistré par le script vedirectOnArduinoRemote.py cohérence avec config-vedirectOnArduinoRemote.yaml data_file: /tmp/PvMonit_getSerialArduino.data.yaml data_file_expir: 300 # Expiration serial: port: /dev/ttyAMA0 # ttyAMA0 pour le serial via GPIO, ttyUSB0 pour le port USB... timeout: 0 # Débit du serial 0 qui va vers l'Arduino (doit être cohérent entre les 2, diffère selon la distance de câble) # Débit Longueur (m) # 2400 60 # 4 800 30 # 9 600 15 # 19 200 7,6 # https://fr.wikipedia.org/wiki/RS-232#Limites baudRate: 4800 whileSleep: 0.001 whileSleepAfterStop: 3 # donnée récolté (voir la doc victron sur le protocole VE.Direct) data_ok: mppt: - CS - PPV - V - ERR - I - VPV - H19 - H20 - H21 - H22 - H23 - Relay bmv: - V - VS - VM - DM - I - T - P - CE - SOC - TTG - AR - H1 - H2 - H3 - H4 - H5 - H6 - H7 - H8 - H9 - H10 - H11 - H12 - H13 - h14 - H15 - H16 - H17 - H18 - Relay phoenix: - P - CS - MODE - AC_OUT_V - AC_OUT_I - WARN wks: enable: false # Passer a true pour activer bin: "/usr/bin/sudo /usr/bin/python3 /opt/PvMonit/bin/wks.py" # Script qui récupère les informations du WKS data: printAll: true # Afficher toutes les valeurs mêmes si elles n'ont pas de libellé QPIRI: # Ordre name: "Paramètre" # Le nom #~ 1: # La position de 1 à X #~ id: ConfGirdRatV # Id : doit être unique, sans caractères spéciaux ni espace, ni accent... #~ desc: "Grid rating voltage" # Description #~ units: "V" # Unité de messur (V / % / A...) #~ regex: /^[0-9]+.[0-9]$/ # Regex a valider sinon la valeur ne s'affiche pas, Si pas de regex, pas de validation #~ hide: true # true = caché, false or null = affiché 1: id: ConfGirdRatV desc: "Grid rating voltage" units: "V" regex: /^[0-9]+.[0-9]$/ 2: id: GirdRatA desc: "Grid rating current" units: "A" #~ regex: false #~ hide: true 3: id: ConfAcOutRV desc: "AC output rating voltage" units: "V" 4: id: ConfAcOutRF desc: "AC output rating frequency" units: "Hz" 5: id: ConfAcOutRI desc: "AC output rating current" units: "A" 6: id: ConfAcOutVA desc: "AC output rating apparent power" units: "VA" 7: id: ConfAcOutRP desc: "AC output rating active power" units: "W" 8: id: ConfBatRV desc: "Battery rating voltage" units: "V" 9: id: ConfBatReCV desc: "Battery re-charge voltage" units: "V" 10: id: ConfBatUV desc: "Battery under voltage" units: "V" 11: id: ConfBatBV desc: "Battery bulk voltage " units: "V" 12: id: ConfBatFV desc: "Battery float voltage" units: "V" 13: id: ConfBatT desc: "Battery type" value2text: 0: "AGM" 1: "Flooded" 2: "User" 14: id: ConfCurMaxACcharge desc: "Current max AC charging current" units: "A" 15: id: ConfCurMaxCharge desc: "Current max charging current" units: "A" 16: id: ConfInputVR desc: "Input voltage range" value2text: 0: "Appliance (From 90V to 280V AC)" 1: "UPS (From 170V to 280V AC)" 17: id: ConfOutputSP desc: "Output source priority" value2text: 0: "Utility first" 1: "Solar first" 2: "SBU first" 18: id: ConfChargeSP desc: "Charger source priority" value2text: 0: "Utility first" 1: "Solar first" 2: "Solar + Utility" 3: "Only solar charging permitted" 19: id: ConfBatReDV desc: "Battery re-discharge voltage" units: "V" QPIGS: name: "Donnée" 1: id: GirdV desc: "Grid voltage" units: "V" regex: /^[0-9]+.[0-9]$/ 2: id: GirdF desc: "Grid frequency" units: "Hz" 3: id: ACoutV desc: "AC output voltage" units: "V" 4: id: ACoutF desc: "AC output frequency" units: "Hz" 5: id: ACoutP desc: "AC output apparent power" units: "VA" 6: id: CONSO desc: "AC output active power" units: "W" 7: id: LOAD desc: "AC output load percent" units: "%" 8: id: BusV desc: "BUS voltage" units: "V" 9: id: V desc: "Battery voltage" units: "V" 10: id: Ic desc: "Battery charging current" units: "A" 11: id: SOC desc: "Battery capacity" units: "%" 12: id: BatFloatV desc: "Battery float voltage" units: "V" 13: id: BatVsoc desc: "Battery voltage from SCC 1" units: "V" 14: id: Id desc: "Battery discharge current" units: "A" 15: id: T desc: "Inverter heat sink temperature" units: "°C" 16: id: IPV desc: "PV Input current 1" units: "A" 17: id: VPV desc: "PV Input voltage 1 " units: "A" 18: id: PPV desc: "PV Charging power 1 " units: "W" 19: id: Status desc: "Device status" QPIWS: name: "Alarme" 1: id: ERR_OC desc: "Over charge current" 2: id: ERR_T desc: "Over temperature" 3: id: ERR_BVU desc: "Battery voltage under" 4: id: ERR_BVH desc: "Battery voltage high" 5: id: ERR_PVHL desc: "PV high loss" 6: id: ERR_BT desc: "Battery temperature too low" 7: id: ERR_BTH desc: "Battery temperature too high" 8: id: ERR_PVLL desc: "PV low loss" 9: id: ERR_PVHD desc: "PV high derating" 10: id: ERR_THD desc: "Temperature high derating" 11: id: ERR_BTA desc: "Battery temperature low alarm" # Numéro de série (champs SER#) en correspondance avec des nom buvables deviceCorrespondance: HQXXXXXXXX: MpttGarage HQYYYYYYYY: MpttToit OTHER: Divers # Plafont de consommation en W impossible à dépasser (techniquement, sinon c'est une erreur de sonde) consoPlafond: 1500 # Tension standard du réseau (110V ou 230V) tensionNorme: 230 ### Export vers Emoncms emoncms: daemon: false # Interval entre 2 récupération de donnée (en minute) getInterval: 5 # Interval entre 2 envoi à emoncms sendInterval: 30 # Test la connexion internet testInternetHost: emoncms.org testInternetPort: 80 # emoncms URL du post.json & API key urlInputJsonPost: https://emoncms.org/input/post.json apiKey: XXXXXXXXXXXXXXXXXXXXXXXX # Répertoire de collecte de données dataCollecte: /tmp/PvMonit_collecteData # Dossier ou ranger les erreurs dataCollecteError: /tmp/PvMonit_collecteDataError # Attente entre deux requête OK sleepOk: 1 # Attente entre deux requête échoué sleepNok: 3 # Fichier de lock pour éviter les doublons lockFile: /tmp/PvMonit_sendToEmoncms.lock ### Page Web : www: # Mot de passe d'accès à la page web password: false # http://www.passwordtool.hu/md5-password-hash-generator passwordLife: 86400 # Durée de vie du mot de passe en seconde # Délais de raffraichissement de la page (en seconde) 300 = 5 minutes refreshTime: 300 # Max de la jauge voltage batterie (en V) vbatMax: 17 # Max de la jauge puissance PV (en W) PpvMax: 500 # max Jauge puissance PV (en W) # Max de la jauge puissance PV total (si plusieurs régulateur) (en W) PpvtMax: 500 # max Jauge puissance PV (en W) dataPrimaire: - V - PPV - ERR - CS - SOC - AR - P - TTG - MODE - AC_OUT_V - AC_OUT_I - WARN - PPVT - CONSO dataPrimaireSmallScreen: - SOC - P - PPVT - PPV menu: -
'.$subTitle.'
'; } else { ?>Monitoring de l'installation solaire électrique